Please note: E2000 is an LSH connector with a dust-proof cover.
Specifications
|
Connector Type |
LC/SC/ST/FC/LSH |
Polish Type |
UPC/APC |
|
Fiber Mode |
OS2 9/125 μm |
Wavelength |
1310/1550 nm |
|
Fiber Count |
Duplex |
Polarity |
A (Tx) to B (Rx) |
|
Fiber Grade |
G.657.A1 (Compatible with G.652.D) |
Min. Bend Radius (Fiber Cable) |
10/5D (Dynamic/Static) |
|
Flame Rating |
Riser (OFCR-Optical Fiber Conductive Riser)/LSZH/Plenum (OFNP) |
Tensile Strength |
120/225N (Long/Short Term) |
|
Insertion Loss |
≤0.3dB |
Return Loss |
UPC≥50dB, APC≥60dB (LC/SC/ST/FC) |
|
Operating Temperature |
-25 to 70°C (-13 to 158℉) |
Storage Temperature |
-25 to 70°C (-13 to 158℉). |
Tough Steel Tube Protects Network Connection Further
Stainless steel tube can provide good protection against optical fiber breakage and be used in a slight oil, gas and moisture environment, which ensure the operation of the network.
Trampling Resistance
Moisture Resistance
Gas Resistance
Oil Resistance
Rodents/Pests Resistance
Carrier-grade Cable with Guaranteed Quality
Superior cable assemblies reduce light loss during cable bending and easily meet your diverse cabling requirements.

10/5D Min. Bend Radius
The G.657.A1 fiber allows tighter cable bends for routing.
Zirconia Ceramic Ferrule
The precision ferrules reach up to 1000 times times insertions lifespan.
120-225N Tensile Strength
The pull-resistant cable prevents breaking and prolongs the life.
Two Polish Types for Various Signal Sensitivity Demands
The fiber endfaces of UPC and APC result in different signal losses. With an 8° angled endface, APC
is more suitable for high precision fiber optic signal applications.
UPC mainly used for TV, telephony and data systems.
APC mainly used for FTTX, PON and other WDM systems.
Three Jacket Materials Used in Diverse Cabling Zone
It's important to know the differences between Plenum (OFNP), Riser (OFCR-Optical Fiber Conductive Riser), LSZH jackets because each different type is used in different locations.

Meet the Various Indoor Installation Needs
Ideal for network cabinet connection, ceiling wiring and under-floor wiring in the data center.